Elastic Networks 600 Especificaciones Pagina 107

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 238
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 106
Elastic Networks 2 BitStorm 1900 Installation and Testing
08-01101-01, Rev. 1.50 BitStorm 1900 Installation and Maintenance Guide 2-85
Task 010: Installing Voice/Data w/Filter 66-Block
Connections
Use this procedure to connect the BitStorm 1900 to the EtherLoop
cross-connect in applications where voice/data service is required with
a Filter 66-Block.
Requirements
This procedure requires the following tools and materials:
5-BitStorm 1900 cable harnesses
5-intermediate cables
Cross-connect block(s) of the same type used in the existing main
distribution frame (MDF)
Cross-connect punch-down tool
Jumper Wire (24AWG)
"Appendix B: Cabling Specifications," on page 143 contains the com-
plete specifications for the cables and wiring required in this procedure.
Step Procedure
1.) Mount 66-blocks on wall in an appropriate area for running jump-
ers.
2.) Verify the room position on frame blocks.
3.) Replace jumpers to 66-Filter Block and retest phone lines.
4.) Refer to Figure 2-17, "Voice/Data Filter 66-Block Connections for
4212 CO Modems," on page 86, Figure 2-18, "Voice/Data Filter 66-
Block Connections for 6306 and 10306 CO Modems," on page 87,
and Figure 2-19, "Voice/Data Filter 66-Block Connections for 6224
and 10224 CO Modems," on page 88.
Vista de pagina 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 237 238

Comentarios a estos manuales

Sin comentarios